absolute newbe

Home Forums TinyG TinyG Support absolute newbe

Viewing 4 posts - 31 through 34 (of 34 total)
  • Author
    Posts
  • #7856
    snooperace
    Member

    Hi Carl

    Here are my motor 2 & 3 settings

    2ma] m2 map to axis 1 [0=X,1=Y,2=Z…]
    [2sa] m2 step angle 1.800 deg
    [2tr] m2 travel per revolution 60.0000 mm
    [2mi] m2 microsteps 8 [1,2,4,8]
    [2po] m2 polarity 1 [0=normal,1=reverse]
    [2pm] m2 power management 2 [0=disabled,1=always on,2=in cycle,3=when moving]
    [3ma] m3 map to axis 1 [0=X,1=Y,2=Z…]
    [3sa] m3 step angle 1.800 deg
    [3tr] m3 travel per revolution 60.0000 mm
    [3mi] m3 microsteps 8 [1,2,4,8]
    [3po] m3 polarity 0 [0=normal,1=reverse]
    [3pm] m3 power management 2 [0=disabled,1=always on,2=in cycle,3=when moving]

    #7857
    cmcgrath5035
    Moderator

    These look OK.
    Just one more suggestion; if you set $2po=0 and $3po=1, any change in action?

    It does seem that the M3 driver is flaky, either intermittent connection or bad device.

    #7861
    snooperace
    Member

    If I change the polarity around there is no change in action still same problem. How does one get a replacement tinyg

    #7863
    cmcgrath5035
    Moderator

    From whom did you buy it?
    If direct from Synthetos, contact them

Viewing 4 posts - 31 through 34 (of 34 total)