matt_o_70

Forum Replies Created

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • in reply to: Help diagnose erratic machine control #9889
    matt_o_70
    Member

    I have been using XP, chilipeppr, Chrome. I just tried using coolterm today to run through the steps on the wiki to try to gain a better understanding of error / reveal any error codes once triggered to help diagnose.

    This same machine (Openbuilds OX) works 100% under parallel port and Mach3 control no errors – but I am trying to move to x64 Win7/10 environment and so trying this TinyG via USB still on the old XP box.

    Still need to set up the Win10 PC – with TinyG/Chilipeppr to see if that changes anything.

    $$ dump as text file:
    https://drive.google.com/open?id=0BxnzhuMpoz3BR2JUM01kYWczak0

    • This reply was modified 8 years, 2 months ago by matt_o_70.
    in reply to: Help diagnose erratic machine control #9885
    matt_o_70
    Member

    Performing the squares $test=3 – I just replicated the Hang condition and get the err: Machine is alarmed – Command not processed when trying to rerun.

    Off to find out how to read or error codes?

    from wiki: “When a limit is hit the machine enters an alarm state and signals this by shutting down all movement and flashing the Spindle Direction LED rapidly.” Since I don’t have a flashing Spindle Dir LED. So I am working on the premise that this is not a falsely triggered limit switch.

    • This reply was modified 8 years, 3 months ago by matt_o_70.
    • This reply was modified 8 years, 3 months ago by matt_o_70.