Shield Grounding

Home Forums TinyG TinyG Support Shield Grounding

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #9049
    mchezz
    Member

    I am setting up limit switches and I have read to ground the shields. Where should they be grounded; the ground terminals on the Tinyg itself?

    #9056
    cmcgrath5035
    Moderator

    That is what I do.
    Connect all the shields to a single 18 to 22ga stranded pigtail, slide the pigtail into the tinyG ground connection point (Vmot -).

    Stranded wire will survive more flexing than solid wire, if you have to use solid, check it occiassionally

    #9063
    mchezz
    Member

    Thanks, that’s what I was thinking of doing.

    #9258
    TarHeelTom
    Member

    But remember. Only ground the shield at the tinyg end. Leave it unconnected at the other ends….